The HAES ESEN-2MAR Esento Marine provides 2 conventional fire detection zones. The programming features include programmable muster alarm zones and a false alarm management mode.
As standard, all Esento Marine 2-4 panels provide two monitored sounder circuits, Fire & Fault VFCO relays and inputs to ring and pulse the sounder circuits.
A separate interface card is also available to connect the panel to a ships voyage data recorder system.
The panels are supplied with a 1.25 amp internal power supply module. This module complies with the requirements of EN54-4 : 1988 and provides temperature-compensated battery management charging.
Esento Marine panels are approved to European standards EN54-2 & 4, Fire Detection and Alarm Systems – Control & Indicating Equipment
Key Features of the ESEN-2MAR |
|---|
| > 2 conventional zones > Activate controls via key switch or code entry > Compatible with Apollo Orbis Marine detectors > Integral detector removal monitoring > Earth fault monitoring > 1.25 Amp switch mode power supply Nom 27V DC > 2 monitored sounder outputs > 2 Aux C/O relays (1 x Fire) (1 x Fault). voltage free > Class change I/P > Alert I/P > Fire & fault switched -ve outputs > False alarm mode > Muster alarm feature > Test mode, with or without sounders > Disable zones, sounder O/Ps & aux O/Ps > Alarm load, 800mA shared between all sounder outputs > All sounder circuits are fused @ 500mA with resettable fuses |
| Brand | HAES Technologies |
|---|---|
| Manufacturer Part No. | ESEN-2MAR |
| Product Series | Esento Marine |
| Primary Power Source | Mains Powered (230V) |
| System Type | Conventional |
| Number of Zones | 2 |
| Colour | Grey |
| Warranty | 3 Years |
| Enclosure | 1.2mm Mild Steel IP30. Colour ref: MW334E Interpon powder coat |
| Cable Entry | Via 20mm knockouts located in the top and rear of the cabinet |
| Dimensions | Back box: 300mm W x 250mm H x 80mm D, Lid: 308mm W x 260mm H x 23mm D |
| Mains Supply | 1.25A internal switch mode power supply, Nom 27v DC |
| Battery Capacity | 2 x 3.2Ah 12v VRSLA |
| Detection Zones | 2 x conventional. EOL = 4K7R |
| Sounder Circuits | 2 x monitored, fused @500mA. EOL = 4K7R |
| On Board Relays | 1 x Fire, 1 x Fault, 3A, 30v volt free changeover |
| Switch Inputs | Class change & alert (pulsing) |
| False Alarm Management | Type A dependency mode, approved by LPCB |
| Muster Alarm | Selectable per zone |