HAES Esento Excel 12 Zone Conventional / Twin Wire Fire Panel (XLEN-12)

SKU
XLEN-12
£494.89 £412.41
HAES Esento Excel 12 Zone Conventional / Twin Wire Fire Panel (XLEN-12)

Product Details for HAES Esento Excel 12 Zone Conventional / Twin Wire Fire Panel (XLEN-12)

The HAES XLEN-12 Esento Excel panel offers 12 Conventional and/or Twin Wire (sav-wire) zones. All inputs and outputs are fully programmable and there are options to have delays to the outputs. The programming features also include 3 different modes to help reduce false alarms.

As standard, the Excel panel provides four monitored sounder circuits, Fire & Fault VFCO relays, Fire & Fault switched negative outputs, class change and an alert input.

A fully functional repeater panel is available via a plug-in comms PCB. Excel panels support a large range of conventional detectors including Apollo, Hochiki & Nittan.

The panels are supplied with a 3.0 amp internal power supply module. This module complies with the requirements of EN54-4: 1988 and provides temperature-compensated battery management charging.

HAES Excel panels are approved to European standards EN54-2 & 4, Fire Detection and Alarm Systems – Control & Indicating Equipment.


Key Features of the XLEN-12

> 12 zones
> Zonal Twin Wire selection by DIL switch
> Network up to 8 control panels
> Activate controls via key switch or code entry
> Integral detector removal monitoring
> 3 Amp switch mode power supply Nom 27V DC
> 4 monitored sounder outputs
> 2 Aux C/O relays (1 x Fire) (1 x Fault). voltage free
> Class change I/P
> Alert I/P
> Fire & fault switched -ve outputs
> Program delays to outputs
> False alarm modes A, B & C
> Test mode, with or without sounders
> Disable zones, sounder O/Ps, aux O/Ps & delays
> Alarm load, 2.4A shared between all sounder outputs
> All sounder circuits are fused @ 500mA with resettable fuses

More information about HAES Esento Excel 12 Zone Conventional / Twin Wire Fire Panel (XLEN-12)

More Information
Brand HAES Technologies
Manufacturer Part No. XLEN-12
Product Series Esento
Primary Power Source Mains Powered (230V)
System Type Conventional/2-Wire
Number of Zones 12
Colour Grey
Warranty 3 Years
Write Your Own Review
You're reviewing:HAES Esento Excel 12 Zone Conventional / Twin Wire Fire Panel (XLEN-12)
Your Rating

Datasheets and Manuals for HAES Esento Excel 12 Zone Conventional / Twin Wire Fire Panel (XLEN-12)

FAQ’s for HAES Esento Excel 12 Zone Conventional / Twin Wire Fire Panel (XLEN-12)

Loading...

 

Ask Question

All questions will be displayed after moderation.

No questions yet. Be the first to ask the question!

Product Specification for HAES Esento Excel 12 Zone Conventional / Twin Wire Fire Panel (XLEN-12)

Enclosure1.2mm Mild Steel IP30. Colour ref: MW334E Interpon powder coat
Cable EntryVia 20mm knockouts located in the top and rear of the cabinet
DimensionsBack box: 450mm W x 300mm H x 85mm D, Lid: 460mm W x 310mm H x 25mm D
Mains Supply3A internal switch mode power supply, Nom 27v DC
Battery Capacity2 x 7.0Ah 12v VRSLA
Detection Zones12 x conventional or Twin Wire. EOL = 4K7R
Sounder Circuits4 x monitored, fused @500mA. EOL = 4K7R
Twin WireSelectable per zone
NetworkingUp to 8 control panels, fault tolerant RS485 communication, requires TPCA05 network card
On Board Relays2 x programmable, 3A, 30v volt free changeover, additional relay provided on high spec zone card
Outputs2 x programmable, 40mA switch -ve, 2 additional outputs provided on high spec zone card
Switch InputsClass change & alert (pulsing)
Event Log40 event history
Intrinsically Safe ModeSelectable per zone
False Alarm ManagementType A, B & C dependency modes, approved by LPCB
Delay TimerOn board programmable delay timer 1-10 mins